Beginner Course 2 · Lesson 2 · Free
Anatomy of a COA, field by field
Every field on a COA is there for a reason. Learn what each one means and what a missing field tells you.
18+ · No peptide sales · No medical advice
From Beginner Course 2: How to Read a COA · about 14 min
Education only. This lesson teaches you to read lab reports. It is not a recommendation of any product, seller, or lab.
Why fields matter
A COA isn’t just a list of good numbers. It’s a chain of facts that connects a specific sample to specific tests done by a specific lab on specific dates. If any link in that chain is missing or doesn’t match, the good numbers don’t mean much.
Here are the fields you’ll find on a well-made COA, grouped into five parts. Lesson 7 shows them all on one annotated example.
Part 1: Who did the testing
| Field | What it means | What to look for |
|---|---|---|
| Lab name and address | The lab that ran the tests | A real, findable lab with a physical address and contact details |
| Accreditation | Which standard (often ISO/IEC 17025), which accreditation body, and a certificate number | A certificate number you can look up; methods that fall within the lab’s scope |
| Report number | The lab’s unique ID for this report | Lets the lab confirm the report is genuine (Lesson 6) |
| Signatures | The analyst who ran the tests and a reviewer who checked them | At least one named, responsible person; often a quality reviewer as well |
| Page numbers | “Page 1 of 3,” etc. | Shows whether pages are missing |
Part 2: What was tested
| Field | What it means | What to look for |
|---|---|---|
| Client | Who sent the sample to the lab | Tells you who chose the sample |
| Sample ID | The lab’s internal code for the sample | Usually different from the lot number; both should appear |
| Sample description | What the client said the sample was | Name of the compound, form (for example, white powder in a sealed vial), amount on the label |
| Lot (batch) number | The production batch the sample came from | Must match the lot number on the product it’s supposed to describe |
| Label claim | The amount the label says is in each unit (for example, “10 mg per vial”) | Needed to judge the quantity result in Lesson 4 |
Many labs note that results are based on the sample “as received.” That’s a reminder that the lab can only report on what it was given.
Part 3: When
| Date | What it means |
|---|---|
| Manufacture date (if given) | When the lot was made, as reported by the client |
| Date received | When the lab got the sample |
| Test dates | When the analyses were run |
| Report date | When the report was issued |
| Expiry or retest date (if given) | A date after which the results shouldn’t be assumed to still hold |
The dates should make sense in order: made → received → tested → reported. A report dated before the sample was received is a problem.
Part 4: How (the methods)
Each result should say which method produced it. Common methods for peptides:
| Method | What it answers | Lesson |
|---|---|---|
| MS (mass spectrometry), often LC-MS (liquid chromatography combined with mass spectrometry) | Identity: is the molecular mass right? | 3 |
| HPLC (high-performance liquid chromatography) with a UV detector | Purity: what share of detected material is the main peptide? | 4 |
| Quantitative HPLC, amino acid analysis, or nitrogen analysis | Quantity / peptide content | 4 |
| Karl Fischer titration | Water content | 4 |
| Ion chromatography | Counter-ions such as TFA or acetate | 4 |
| LAL (Limulus amebocyte lysate) or recombinant reagents | Bacterial endotoxin | 5 |
| Sterility test (growing samples in culture) | Living microbes | 5 |
| ICP-MS (inductively coupled plasma mass spectrometry) | Heavy metals and other elements | 5 |
| GC (gas chromatography), often “headspace” GC | Residual solvents | 5 |
A good report names the method, not just the test. “Purity: 99%” with no method is much weaker than “Purity (HPLC-UV, 220 nm): 98.6%.”
Part 5: The results
Each test should have three things side by side:
- Result: the number or finding (for example, “98.6%” or “Conforms”).
- Specification (also called acceptance criteria): the target the result was judged against (for example, “≥ 98.0%”).
- Pass/fail or conclusion: whether the result met the specification.
Watch for these patterns:
- A result with no specification tells you what was measured but not what counts as acceptable.
- A specification with no result is just a promise.
- “Not tested” or a blank is not the same as “passed.” It means nobody looked.
- Units matter. Purity is a percentage of detected material. Quantity is in milligrams or a percentage of the label claim. Endotoxin is in EU (endotoxin units) per milligram or per unit. Metals are often in micrograms per gram or parts per million (ppm).
The “results relate only to the sample tested” statement
Many lab reports include a line like “These results relate only to the item(s) tested.” That isn’t the lab being cagey. It’s an honest description of what any lab report can do, and it’s the same idea from Lesson 1.
Self-check
Ungraded. Reveal each answer after you try the question. No certificate.
1. What is the difference between the sample ID and the lot number?
Answer: The sample ID is the lab’s internal code for the sample it received. The lot number identifies the production batch. Both should appear, and the lot number should match the product.
2. A COA lists “Purity: 99.2%” with no method and no specification. What’s missing, and why does it matter?
Answer: The method (how purity was measured) and the specification (what counts as passing). Without them, you can’t judge what the number means or whether it met a standard.
3. A safety test says “Not tested.” Did the product pass that test?
Answer: No. “Not tested” means the test wasn’t done, so there’s no information either way.
Log in or join to track your progress.Self-check is open to all. Progress tracking needs an account.
References
- Vergote V, et al. Quality specifications for peptide drugs: a regulatory-pharmaceutical approach. J Pept Sci. 2009. PMID 19750489.
- ISO/IEC 17025:2017, General requirements for the competence of testing and calibration laboratories. https://www.iso.org/standard/66912.html
- Bachem. Quality control of amino acids and peptides: a guide (technical explainer of identity, purity, water by Karl Fischer, counter-ions by ion chromatography, net peptide content). https://www.bachem.com/knowledge-center/quality-control-of-amino-acids-peptides-a-guide/
- FDA. Pyrogen and Endotoxins Testing: Questions and Answers (guidance, 2012). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/pyrogen-and-endotoxins-testing-questions-and-answers
- ICH Quality Guidelines (Q3C residual solvents; Q3D elemental impurities). https://www.ich.org/page/quality-guidelines
Official labels and foreign registration documents are cited only for their regulatory and study facts. Peptide Student does not provide usage instructions.
B2 Lesson 2 check: Anatomy of a COA, field by field
Log in or join free to take this quiz. Your progress is saved to your account so you only retake what you missed.
Badges and certificates record educational completion only. They are not a professional credential or medical qualification.