Skip to content
PSPeptide
Student
LibraryCoursesBeginner CoursesField NotesAboutJoin

Beginner Course 2 · Lesson 7 · Free · Draft for review

Annotated example COA, checklist, and knowledge check

Put it all together on one fully annotated example report, then take the checklist with you.

18+ · No peptide sales · No medical advice

From Beginner Course 2: How to Read a COA · about 18 min

EXAMPLE – FICTIONAL DATA. The report below was made up for teaching. The lab, lot, client, report number, and results are fictional and do not describe any real product, seller, or laboratory. The compound name and expected masses come from the published BPC-157 sequence so the math is realistic. Nothing here is a recommendation to obtain or use any substance.

The example report

Annotated example certificate of analysis, clearly labeled EXAMPLE – fictional data, with numbered calloutsA mock certificate of analysis labeled EXAMPLE – FICTIONAL DATA at the top, bottom, and as a watermark. It shows a fictional lab with ISO/IEC 17025 certificate EXAMPLE-0000, report number and verification code, client Example Client LLC, sample EX-S-0001, lot EX-LOT-0001, label claim 10 mg peptide per vial, and dates in March 2026. The results table lists LC-MS identity 1418.711 vs 1418.704 daltons (5.1 ppm, conforms), HPLC purity 98.6 percent, net peptide content 82.4 percent with water 5.8 and acetate 10.1 percent, amount per vial 9.6 mg (96 percent of claim), endotoxin below 0.50 EU per mg against a client-defined limit, sterility not tested, heavy metals below 0.10 micrograms per gram, residual solvents not tested, fentanyl screen not requested, fictional signatures, and page 1 of 1. Seventeen numbered callouts match the lesson table.EXAMPLE – FICTIONAL DATAEXAMPLE – FICTIONAL DATA · FOR TEACHING ONLY · NOT A REAL LAB, LOT, OR PRODUCTExample Analytical Laboratory (fictional)1123 Example Street, Sample City · ISO/IEC 17025 accredited, certificate no. EXAMPLE-0000CERTIFICATE OF ANALYSISReport no. EX-R-0000-0001 · Verification code EX-VERIFY-00002ClientExample Client LLC (fictional)3Sample ID / LotEX-S-0001 / EX-LOT-00014Sample descriptionBPC-157 (example), lyophilized powder, 1 vialLabel claim10 mg peptide per vial5DatesReceived Mar 2, 2026 · Tested Mar 4–6, 2026 · Reported Mar 9, 20266Test (method)ResultSpecificationConclusionIdentity (LC-MS)Mono. mass obs. 1418.711 Daexp. 1418.704; Δ 5.1 ppm[M+2H]²⁺ m/z 710.363≤ 10 ppmConforms7Purity (HPLC-UV, 220 nm)98.6% (area)largest impurity 0.6%≥ 98.0%Conforms8Net peptide content82.4%Water (KF) 5.8% · Acetate 10.1%Report resultReported9Amount per vial (quant. HPLC)9.6 mg (96% of claim)90–110% of claimConforms10Endotoxin (LAL)< 0.50 EU/mg(kinetic chromogenic)Client-definedConforms11SterilityNot tested——12Elemental impurities (ICP-MS)Pb, As, Cd, Hg each< 0.10 µg/gReport resultReported13Residual solventsNot tested——14Fentanyl screenNot requested——15Analyst: A. Example (fictional) · QA review: B. Example (fictional) · Signed Mar 9, 202616Results relate only to the item tested. This report may not be reproduced except in full.Page 1 of 1 · Attachment: HPLC chromatogram17EXAMPLE – FICTIONAL DATA · Numbered callouts are explained in the lesson table
Annotated example certificate of analysis, clearly labeled EXAMPLE – fictional data, with numbered callouts

Reading it callout by callout

# Field on the example What it tells you What a careful reader checks
1 Lab name, address, ISO/IEC 17025 accreditation, certificate no. Who tested the sample and what standard they claim Is the lab findable on its own? Does the accreditation body’s directory list this certificate number, and do the methods below fall in its scope?
2 Report no. and verification code The lab’s unique ID for this report Look it up on the lab’s own website (typed in yourself), or ask the lab
3 Client: “Example Client LLC (fictional)” The party that sent the sample The client chose the sample. Was it pulled from ordinary stock or hand-picked?
4 Sample ID EX-S-0001 and Lot EX-LOT-0001 Lab’s code for the sample, and the production batch The lot number must match the product label exactly
5 Label claim: 10 mg peptide per vial What the label promises Note the basis: peptide, not powder (Lesson 4)
6 Dates: received Mar 2, tested Mar 4–6, reported Mar 9, 2026 The timeline Dates are in a sensible order. Note there’s no expiry or retest date on this report
7 Identity (LC-MS): expected monoisotopic 1418.704 Da; observed 1418.711 Da; difference 5.1 ppm; spec ≤ 10 ppm; Conforms The main molecule’s mass matches the expected formula Mass type is stated (monoisotopic). The observed 2+ ion (m/z 710.363) is consistent. The tolerance fits a high-resolution instrument. MS can’t confirm sequence order (Lesson 3)
8 Purity (HPLC-UV, 220 nm): 98.6%; spec ≥ 98.0%; largest single impurity 0.6% Share of detected peak area that’s the main peak Method and wavelength are stated, and a chromatogram is attached. 1.4% total impurity
9 Net peptide content 82.4%; water (Karl Fischer) 5.8%; acetate 10.1% How much of the powder is peptide vs water and counter-ion Adds up to about 98%, which is plausible. Acetate salt, so TFA was exchanged out
10 Amount per vial (quantitative HPLC): 9.6 mg; 96% of label claim; spec 90–110% Actual peptide measured in the tested vial Within spec. Based on the vials tested, not every vial in the lot
11 Endotoxin (LAL, kinetic chromogenic): < 0.50 EU/mg; spec: client-defined Endotoxin was below the test’s measurable level The limit was set by the client, not by a regulator. A “pass” here means “met the client’s own target”
12 Sterility: Not tested No information about living microbes “Not tested” is not a pass
13 Elemental impurities (ICP-MS): Pb, As, Cd, Hg each < 0.10 µg/g; spec: report result The four metals of highest concern were below the measurable level No acceptance limit was applied; the lab just reported values
14 Residual solvents: Not tested No information about leftover synthesis solvents Not a pass
15 Fentanyl screen: Not requested The client didn’t ask for this screen Not a pass
16 Signatures (analyst and QA reviewer) and “results relate only to the item tested” Named people took responsibility; scope statement Matches what a real accredited report typically includes
17 Page 1 of 1, chromatogram attached The whole report is here Confirms nothing is missing

What this example COA actually supports

If it were real and verified, this report would support these statements, and only these:

  • The tested sample from lot EX-LOT-0001 contained a molecule with the expected mass.
  • About 98.6% of the detected peptide material was the main peak.
  • The tested vial held about 9.6 mg of peptide.
  • Endotoxin and four heavy metals were below the measurable levels in the tested sample.

It would not support:

  • that every vial in the lot is the same,
  • that the product is sterile or free of residual solvents (not tested),
  • that the product is safe, effective, or appropriate for any use.

Your COA checklist

Use this list on any COA. A “no” isn’t automatically disqualifying, but every “no” is a gap you now know about.

The chain of facts

  • ☐ Lab name, address, and contact information are present, and the lab is findable on its own
  • ☐ Accreditation body and certificate number are listed, and the methods are in the lab’s scope
  • ☐ Report number or verification code can be checked with the lab directly
  • ☐ Client is named
  • ☐ Lot number matches the product exactly
  • ☐ Dates are present and in a sensible order

The tests

  • ☐ Identity: method named; expected and observed mass both shown; mass type (average or monoisotopic) stated; difference within a stated tolerance
  • ☐ Purity: HPLC method and wavelength named; chromatogram attached; largest single impurity reported
  • ☐ Quantity: amount per vial or % of label claim measured (not just the label number); basis stated (peptide vs powder)
  • ☐ Net peptide content, water, and counter-ion (TFA or acetate) reported
  • ☐ Endotoxin: result, units, method, and who set the limit
  • ☐ Sterility, metals, solvents, and other screens: tested, or clearly marked as not tested

Red-flag scan

  • ☐ No “too perfect” numbers (exactly 100%, impossible precision, identical results across lots)
  • ☐ No signs of editing (font shifts, cropping over key fields)
  • ☐ Online copy from the lab matches the copy you have

Knowledge check

Try each question before revealing the answer. Ungraded and just for you.

>
  • What is the single most important limit of any COA?
  • <

    Answer: It describes the sample that was tested. It only applies to another vial if that vial truly came from the same lot and the sample truly represented that lot.

    start=”2″>
  • What’s the difference between in-house and third-party testing, and what question should you still ask about third-party tests?
  • <

    Answer: In-house means the maker tests its own product; third-party means an independent lab does. You should still ask who chose and sent the sample.

    start=”3″>
  • A peptide’s expected average mass is 1419.54 Da and its expected monoisotopic mass is 1418.70 Da. A COA compares an observed monoisotopic mass of 1418.71 to the average mass and reports a 0.83 Da “error.” What went wrong?
  • <

    Answer: The COA compared two different mass types. Compared with the correct (monoisotopic) expected value, the error is only about 0.01 Da.

    start=”4″>
  • What does an MS identity test not tell you?
  • <

    Answer: Any of: sequence order for same-mass variants; leucine vs isoleucine; D vs L forms; how much peptide is present; overall purity.

    start=”5″>
  • “Purity 99%.” What is that a percentage of?
  • <

    Answer: The total HPLC peak area detected at the chosen UV wavelength. It’s not a percentage of the powder’s weight.

    start=”6″>
  • Why can a very pure peptide have a net peptide content of only 75%?
  • <

    Answer: The powder also contains water and counter-ions (like TFA or acetate). Peptides with many positively charged amino acids carry more counter-ions.

    start=”7″>
  • Name one thing an endotoxin test detects that a sterility test doesn’t.
  • <

    Answer: Endotoxin from dead bacteria. A sterility test only detects living microbes.

    start=”8″>
  • A COA shows “Sterility: —” (a dash). How should you read that?
  • <

    Answer: As “not tested” or “no information,” not as a pass.

    start=”9″>
  • Give two ways to check that a COA is genuine.
  • <

    Answer: Any two of: match the lot number to the product; look up the lab independently; check the accreditation certificate and scope in the accreditation body’s directory; use the verification code on the lab’s own website (typed in yourself); contact the lab.

    start=”10″>
  • A verified, accredited, third-party COA shows excellent results. Does that mean the substance is safe and works?
  • <

    Answer: No. It means one tested sample matched certain quality measurements. Safety and effects in people are separate questions that need clinical evidence (Beginner Course 3).

    Self-check is open to all. Progress tracking needs an account.

    References

    • Vergote V, et al. Quality specifications for peptide drugs: a regulatory-pharmaceutical approach. J Pept Sci. 2009. PMID 19750489.
    • D’Hondt M, et al. Related impurities in peptide medicines. J Pharm Biomed Anal. 2014. PMID 25044089.
    • Cox HD, et al. Detection and in vitro metabolism of the confiscated peptides BPC 157 and MGF R23H. Drug Test Anal. 2017. PMID 28035768. (Sequence source for the example’s expected masses.)
    • Zubarev R, Mann M. On the proper use of mass accuracy in proteomics. Mol Cell Proteomics. 2007. PMID 17164402.
    • FDA. Pyrogen and Endotoxins Testing: Questions and Answers (guidance, 2012). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/pyrogen-and-endotoxins-testing-questions-and-answers
    • ICH Quality Guidelines: Q3C and Q3D. https://www.ich.org/page/quality-guidelines
    • ISO/IEC 17025:2017. https://www.iso.org/standard/66912.html

    Official labels and foreign registration documents are cited only for their regulatory and study facts. Peptide Student does not provide usage instructions.

    B2 Lesson 7 check: Annotated example COA, checklist, and knowledge check

    3 multiple-choice questions · you need every question correct · unlimited retakes · on a retake you only re-answer the ones you missed. Education only.

    Checkpoint for B2 Lesson 7. Education only.

    Log in or join free to take this quiz. Your progress is saved to your account so you only retake what you missed.

    Log in · Join free

    Badges and certificates record educational completion only. They are not a professional credential or medical qualification.

    B2 final: How to Read a COA

    10 multiple-choice questions · you need every question correct · unlimited retakes · on a retake you only re-answer the ones you missed. Education only.

    Final quiz for Beginner Course 2. Education only.

    Log in or join free to take this quiz. Your progress is saved to your account so you only retake what you missed.

    Log in · Join free

    Badges and certificates record educational completion only. They are not a professional credential or medical qualification.